We are proud to announce the new multi-purpose REVO FC which combines the complete REVO 80 functionality with a Fundus Camera. A single versatile device featuring high resolution OCT and true color fundus imaging for time and space efficiency.

The built-in 12.3 Mpix camera guarantees excellent image reproduction. REVO  FC meets all requirements for modern optical tomographs.

For additional product info, download brochure now.

Categories: Ophthalmology, OPTOPOL
  • Description
  • Additional information

Description

Fundus Camera with the complete REVO 80 functionality
The combination of an All in One OCT technology with a Full Color Fundus Camera in one compact system gives you high quality OCT images and a detailed color image for a multipurpose diagnosis.
Capturing color fundus images of retina and OCT scanning of a retina in a single shot on one device saves both time and space.

Now you can use the REVO FC  in the way you need it:

  • as a Full Color Fundus Camera
  • as a combo providing simultaneous OCT and fundus images
  • only for high quality OCT imaging including OCT-A
  • as a Biometry device

REVO FC offers all proven advantages of REVO systems with a cutting-edge color Fundus imaging for a new level of diagnostic certainty. High quality OCT scanning and a comprehensive analysis of the retinal layers combined with a Fundus imaging make the examination versatile as never before.

What makes the REVO FC truly unique is its integrated non-mydriatic 12.3 Mpix Fundus Camera capable of capturing ultra-high quality and detailed color images. The REVO FC Fundus Camera is fully automated, safe and easy to use.

  • The advanced optical system ensures high quality imaging at as wide as 45° viewing angle.
  • A Color Fundus image capturing is possible with a pupil as small as 3.3 mm. An OCT  scan is possible even on a 2.4 mm pupil.
  • Easy to use image processing tools such as  RGB channel, brightness, contrast, gamma and sharpness adjusters used with filters deliver a stunning retinal image.
  • Available view modes present detailed photos of a single or both eyes as well as a time comparison of the fundus photos.

 

OPTICAL COHERENCE TOMOGRAPHY
REVO FC with  80 000 A-scan/sec scanning speed offers advanced technologies and remarkable simplicity of operation. It meets all requirements for modern optical tomographs.

RETINA
Single 3D Retina examination is enough to perform both Retina and Glaucoma analysis based on retinal scans. Software automatically recognizes 8 retina layers. Thus allowing a more precise diagnosis and mapping of any changes in the patient’s retina condition.

GLAUCOMA
Comprehensive glaucoma analytical tools for quantification of the Nerve Fiber Layer, Ganglion layer and Optic Head with DDLS allow for the precise diagnosis and monitoring of glaucoma over time.
With the golden standard 14 optic nerve parameters and a new Rim to Disc and Rim Absence the description of ONH condition is quick and precise.
Advanced view which provides combined information from Retina and Disc scan to integrate details of the Ganglion cells, RNFL, ONH in a wide field perspective for comprehensive analysis.

Advance Retina & ONHONH Single
GLAUCOMA Advance Retina & ONHGLAUCOMA ONH Single

Asymmetry Analysis of Ganglion layers between hemi-spheres and between eyes allows easier identification and detection of glaucoma in early stages and in non-typical patients.

Ganglion BothGanglion Progression
GLAUCOMA Ganglion BothGLAUCOMA Ganglion Progression

Implemented the DDLS  – Disc Damage Likelihood Scale which use 3 separate classification for small, average and large discs. It supports the practitioners in a quick and precise evaluation of the patient’s glaucomatous disc damages.

ONH BothONH Progression
GLAUCOMA ONH BothGLAUCOMA ONH Progression

COMPLET YOUR GLAUCOMA REPORT
To eliminate common problem with the understanding of the patient’s IOP pachymetry module provides IOP Correction value.  With the implemented Adjusted IOP formula you can quickly and precisely understand the measured IOP value.
As the Pachymetry and Anterior Chamber Angle Verification require no additional attachments, the predefined Glaucoma protocol, which consists of Retina, Disc and Anterior scans, can be done automatically to reduce patient chair time.

Closing angleAnterior single view
Closing angleAnterior single view
  * Images courtesy of Prof. Edward Wylęgała MD, PhD

ANTERIOR
For standard examination no additional lens is required. Additional adapter provided with the device allows to make wide scans of anterior segment.

Cornea singleCornea both
ANTERIOR Cornea single ANTERIOR Cornea both
Cornea ComparisonCornea Progression
Anterior Cornea ComparisonAnterior Cornea Progression

FOLLOW UP
High density of standard 3D scan allows to precisely track the disease progression. Operator can analyze changes is morphology, quantified progression maps and evaluate the progression trends.

 

Progression MorphologyProgression Quantification
FOLLOW UP Progression Morphology FOLLOW UP Progression Quantification

COMPARISON
Comparison view allows in easy and convince way to review results from two visits. The view is available for most of the scan programs.


NETWORKING

A proficient networking solution increases productivity and an enhanced patient experience. It allows you to view and manage multiple examinations from review stations in your practice. Effortlessly helping to facilitate patient education by allowing you to interactively show examination results to patients. Every practice will have different requirements which we can provide by tailoring a bespoke service. There is no additional charge for the server module.

DICOM
Store, exchange, and transmit results through DICOM gateway to the hospital network.

LEARN MORE ABOUT OPTIONAL SOFTWARE MODULES

 

  • OCT Angiography
    This module allows visualization of the retinal microvasculature. Angiography SOCT is a non-invasive, dye-free technique providing 3D image of retinal blood circulation.

 

 

  • BIOMETRY OCT 
    B-OCT™ innovative method of using the  posterior OCT device to measure ocular structure along eye axis.

 

 

  • TOPOGRAPHY OCT 
    T-OCT™ is a pioneering way to provide detailed corneal Curvature maps by using posterior dedicated OCT.

 

 

Additional information

Photography type

Color ( FUNDUS CAMERA )

Angle of view

45° ± 5% ( FUNDUS CAMERA )

Min. pupil size for fundus

3.3 mm or more ( FUNDUS CAMERA )

Camera

Builit-in 12-megapixel CCD camera ( FUNDUS CAMERA )

Technology

Spectral Domain OCT

Light Source

SLED, Wavelength 830nm

Bandwidth

50 nm half bandwidth

Scanning speed

80 000 measurements per second

Axial resolution

5 μm in tissue ~2,6 μm digital

Transverse Resolution

12 μm, typical 18 μm

Overall scan depth

2.4 mm

Focus adjustment range

-25D to +25D

Scan range

Posterior 5-12 mm, Angio 3-9 mm, Anterior 3-16 mm

Scan types

3D, Angio, Radial (HD), B-scan (HD), Raster (HD), Cross (HD), TOPO, AL

Fundus alignment

IR, Live Fundus Reconstruction

Alignment method

Fully automatic, Automatic, Semi Manual

Retina analysis

Retina thickness, Inner retinal thickness, Outer retinal thickness RNFL+GCL+IPL thickness, GCL+IPL thickness, RNFL thickness RPE deformation, IS/OS thickness

Angiography OCT

Supercial plexus, RPCP, Deep Plexus, Outer Retina, Choriocapilaries, Depth Coded, Custom, Enface, Thickness map, FAZ, VFA

Glaucoma analysis

RNFL, ONH morphology, DDLS, Ganglion analysis as RNFL+GCL+IP and GCL+IPL, OU and Hemisphere asymmetry

Angiography mosaic

Acquistion method: Auto, Manual, Mosaic modes: 10×6 mm, manual up to 12 images

Biometry OCT

AL, CCT, ACD, LT

Connectivity

DICOM Storage SCU, DICOM MWL SCU, CMDL, Networking

Fixation target

OLED display (The target shape and position can be changed), External fixation arm

Dimensions (WxDxH)

367 x 480 x 504 mm

Weight

30 kg

Power supply

100 – 240 V, 50/60 Hz, 115-140 VA

Related products

  • FLUX

  • REVO NX

  • SOCT COPERNICUS REVO

  • Dental
    • LightMed
  • Dermatology
    • LightMed
  • Interventional Radiology
    • Matek
  • Ophthalmology
    • COMPEX
    • Emtron
    • Imaging Eyes
    • Lightmed
    • Microvision
    • OPTOPOL
    • POTEC
    • SAV IOL
    • SBM

Clinic Resources

  • Optopol Clinic Resources
  • Lighmed Clinic Resources

Latest News & Events

  • 15th Birthday Dec 28

    Parsdidegan has recently celebrated 15th Birthday together with professional team...

  • JETT Plasma Lift Medical Dec 16

    JETT Plasma training course in Prague Dec.2019

  • 29TH ANNUAL CONGRESS OF THE IRANIAN SOCIETY OF OPHTHALMOLOGY Dec 1

    Mashad – Iran/19-22 Nov. 2019          ...

Copyright ©2019 all rights reserved
Designed by Amin Bassam