MicroVision

 

\r\n

\r\n

\r\n

 

\r\n

PTS 1000

\r\n

Automated Perimeter PTS 1000 is a modern diagnostic instrument for precise and fast testing of field of vision. It offers static and kinetic stimuli with all Goldman stimuli sizes and all stimuli colors used in perimetry.  Wide range of strategies and analysis tools combined with intuitive interface gives you powerful diagnostic tool which handling you will enjoy.  Built in maps and possibility of creating own one gives possibility to examine only these areas, which are necessary.  With PTS1000 examination doesn’t have to be tiring anymore.

\r\n

\r\n

FEATURES

\r\n
    \r\n
  • STANDARD VISION TESTS - Depending on chosen test strategy, it enables to define the sensitivity threshold of retina in a given area, as well as to make a fast screening test. Accurate threshold, Intelligent fast threshold, Screening and quick 3-zone can be selected according to needs and patient’s condition.  
  • \r\n
  • TIME SAVING - Fast threshold strategy which utilizes special algorithm allows quicker examination without loss in accuracy. Additional ‘Reduced Field’ and ‘Neurological Field Reduction’ further shorten examination time.
  • \r\n
  • FLICKERING TEST - The device also enables examination by means of flickering stimuli for CFF (Critical Fusion Frequency) measurement. CFF is used as an index of fatigue and it is clinically applied to neuro-ophthalmologic disorders derived from optic nerve disorder especially, diagnosis and evaluation of glaucoma. 
  • \r\n
  • KINETIC TESTS - Thanks to kinetic strategy it is possible to examine hardly cooperating patients with big defects for which static examination is difficult to perform. 4 stimuli colours, 5 Goldmann sizes, adjustable stimuli velocity, silent operation,  built in programs together with option of retesting arbitrary vectors defined by user makes PTS1000 a top product for kinetic perimetry.
  • \r\n
  • SWAP - It enables to use "blue on yellow" (SWAP) examination method, red stimuli perimetry and green stimuli perimetry. This method utilizes fact of Earlier loss of sensitivity to colour based stimuli than to white-on-white stimuli based testing in patients with ophthalmic disease. 
  • \r\n
  • BINOCULAR CAPABILITIES - Implemented BSV strategy allows examination of diplopy areas. Testing of drivers is also possible thanks to included extendend field, that enables testing field up to 80 degrees temporally and Binocular Drivers Test.
  • \r\n
  • AUTODIAGNOSTIC - Built-in autodiagnostic system will automatically detect any damages to device's hardware and report it to the user. 
  • \r\n
  • \r\n

    RESULTS PRESENTATION

    \r\n
    Test result is presented as four easy-to-interpret graphic charts, two of them are related to age norm and standard deviation. Results can be analyzed in form of numerical maps of sensitivity in dB or in intuitive dot scale. Also color presentation is possible for faster identification of regions out of norm.
    \r\n


    ANALYSIS TOOLS

    \r\n
    Test result printout contains also additional information useful for interpretation, such as mean defect, pattern defect, Bebie curve, defects progress analysis, and hill of vision slope. 
    \r\n


    RELIABILITY

    \r\n
    Examination reliability can be estimated on the basis of false negative and false positive tests. Built-in digital camera allows eye-detection during examination and during setting patient’s position, thanks to pupil tracking system it allows a continuous automatic control of fixation. When patient losses fixation blind spot is examined and special attraction mechanism turned on.
    Well known Heijl-Krakau method allows tracking of a blind spot and monitoring of examination reliability.\r\n

     

    \r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n
    Examination bowl300 mm radius, closed type, ventilated
    Tested field range100 deg (160 with fixation shift for drivers test)
    Stimulus sizeGoldmann Sizes I-V
    Stimulus colourswhite, red, green, blue
    Stimulus speed in kinetic perimetry\r\n

    2-10deg/s

    \r\n
    Maximum Stimulus intensity10000 asb
    Fixation method control of blind spot position or digital detection of pupil position 
    Patient response time adaptive to patient speed or set manually from 0,1 to 7,5s 
    Background illuminationdepends on stimuli type-31,5 asb for white and red stimuli, 10 asb for green, 314 asb yellow background for blue stimuli, set automatically 
    Fields\r\n
      \r\n
    • 24, 30
    • \r\n
    • Full (50° in every directions)
    • \r\n
    • Central (30° in horizontal axis and 22° in vertical axis)
    • \r\n
    • Glaucoma (30° with extend up to 50° in nasal direction)
    • \r\n
    • Peripheral (from 30° to 50°)
    • \r\n
    • Macula (up to 10°)
    • \r\n
    • Extended (special field for drivers examination – 50° in nasal direction; 80° in temporal direction)
    • \r\n
    • Fast (up to 30° with scarce points)
    • \r\n
    • Binocular Drivers Test (up to 80° in horizontal axis, up to 50° in vertical axis)
    • \r\n
    • User (up to 50° user defined)
    • \r\n
    • Kinetic (50° in every directions)
    • \r\n
    \r\n
    Strategies\r\n
      \r\n
    • Threshold
    • \r\n
    • Fast Threshold
    • \r\n
    • Advanced
    • \r\n
    • Screening 
    • \r\n
    • 3-zone 
    • \r\n
    • BSV (Binocular Single Vision) 
    • \r\n
    • Flicker (Critical Fusion Frequency)
    • \r\n
    • Blue On Yellow (SWAP)
    • \r\n
    • BDT (Binocular Drivers Test )\r\n
        \r\n
      • Reduced field option
      • \r\n
      • Neurological defects option
      • \r\n
      \r\n
    • \r\n
    • Kinetic
    • \r\n
    \r\n
    Result maps\r\n
      \r\n
    • absolute level
    • \r\n
    • hill of vision deviation
    • \r\n
    • age norm deviation
    • \r\n
    • pattern deviation
    • \r\n
    • total deviation
    • \r\n
    • pattern deviation probability
    • \r\n
    • total deviation probability
    • \r\n
    • defects progress analysis
    • \r\n
    • results comparison
    • \r\n
    • Bebie curve
    • \r\n
    • 3D visualization of patients HOV
    • \r\n
    \r\n
    InterfaceUSB 
    Dimensions693 x 585 x 444  HxWxD  
    Operating Voltage100-250V 50-60Hz 
    Additional fetures\r\n
      \r\n
    • Eye monitoring by means of built-in video camera
    • \r\n
    • Auto-detection of eye position
    • \r\n
    • Automatic pupil diameter measurement
    • \r\n
    • Automatically controlled chin-rest enables to set proper patient’s position precisely and easily
    • \r\n
    • Freely customized advanced Printout Manager with 15 predefined templates and user defined template
    • \r\n
    • Printer-recommended ink jet or laser
    • \r\n
    • Self-diagnostic function checking instrument's efficiency
    • \r\n
    • Ergonomic design ensures comfortable patient position during examination
    • \r\n
    • Special ventilation system is used to keep fresh air throughout examination inside stimulation bowl
    • \r\n
    \r\n
    \r\n
    \r\n
  • \r\n
\r\n

 

Matek Trocar needle is an aspiration needle with unique tip design which allows to obtain core samples for histologic evaluation. Features are briefly as follows

\r\n

 

\r\n
    \r\n
  • User-friendly design
  • \r\n
  • Accurate depth placement with centimeter marks
  • \r\n
  • Echogenic tip
  • \r\n
  • Clear and color coded needle hub design
  • \r\n
\r\n

 

\r\n

\r\n

\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n
\r\n

Catalog Number

\r\n
\r\n

Diameter (G)

\r\n
\r\n

Length (mm)

\r\n
\r\n

MTB1610

\r\n
\r\n

16

\r\n
\r\n

100

\r\n
\r\n

MTB1615

\r\n
\r\n

16

\r\n
\r\n

150

\r\n
\r\n

MTB1620

\r\n
\r\n

16

\r\n
\r\n

200

\r\n
\r\n

MTB1625

\r\n
\r\n

16

\r\n
\r\n

250

\r\n
\r\n

MTB1810

\r\n
\r\n

18

\r\n
\r\n

100

\r\n
\r\n

MTB1815

\r\n
\r\n

18

\r\n
\r\n

150

\r\n
\r\n

MTB1820

\r\n
\r\n

18

\r\n
\r\n

200

\r\n
\r\n

MTB1825

\r\n
\r\n

18

\r\n
\r\n

250

\r\n
\r\n

MTB2010

\r\n
\r\n

20

\r\n
\r\n

100

\r\n
\r\n

MTB2015

\r\n
\r\n

20

\r\n
\r\n

150

\r\n
\r\n

MTB2020

\r\n
\r\n

20

\r\n
\r\n

200

\r\n
\r\n

MTB2025

\r\n
\r\n

20

\r\n
\r\n

250

\r\n
\r\n

Special sizes are avaible upon your request

1984

SOCT Copernicus REVO

\r\n

Our supreme experience in Spectral Domain OCT allows us to provide the market with the modern OCT offering remarkable simplicity of operation. The new SOCT Copernicus REVO meets all demands in daily routine practice.

OCT made simple as never before. All it must be done is to position the patient and press the START button to acquire examinations of both eyes. The device will make examination independently.

Small system footprint, various operator and patient positions allow to install SOCT Copernicus REVO even in the smallest examination room. Variety of review and analysis tool give the operator a choice of using it as a screening or as an advanced diagnostic device.

The noise reduction technology provides the finest details proven to be important for early disease detection.

\r\n
\r\n

 

\r\n

RETINA

\r\n

Single 3D Retina examination is enough to perform both Retina and Glaucoma analysis based on retinal scans.

\r\n
\r\n

 

\r\n

Software automatically recognize 8 retina layers. Thus allowing a more precise diagnosis and mapping any changes in the patient’s retina condition.

\r\n
\r\n

 

\r\n

GLACUOMA

\r\n

Comprehensive glaucoma analysis tools for Quantification of Optic Nerve Head, Retina Nerve Fiber Layer, DDLS, Ganglion layer and Asymmetry

\r\n
\r\n

 

\r\n

ANTERIOR 

\r\n

For standard examinations no additional lens is required.
Additional adapter provided with the device allows to make wide scans of anterior segment.

\r\n
\r\n

 

\r\n

FOLLOW UP

\r\n

High density of standard 3D scan allows to precisely track the disease progress. Operator can analyze changes is morphology, quantified progression maps or evaluate the progression trends.

\r\n
\r\n

 

\r\n

NETWORKING

\r\n

A proficient networking solution increases productivity and an enhanced patient experience. It allows you to view and manipulate multiple examinations from review stations in your practice. Effortlessly helping to facilitate patient education by allowing you to interactively show examination results to patients. Every practice will have differing requirements which we can provide by tailoring a bespoke service. There is no additional charge for the server module.

\r\n

TECHNICAL DATA

\r\n

 

\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n
TechnologySpectral Domain OCT
Light SourceSLED, Wavelength 840nm
Bandwidth50 nm half bandwidth
Scanning speed27000 A-scan per second
Axial resolution5 µm in tissue
Transverse Resolution12 µm, typical 18 µm
Overall scan depth2.4 mm
Scan range3 to 12 mm
Scan types3D, Radial, B-scan, Raster, Cross
Fundus imageLive Fundus Reconstruction
Alignment methodFully automatic, Semi-automatic
Retina analysisRetina thickness, Inner retinal thickness, Outer retinal thickness, RNFL+GCL+IPL thickness, GCL+IPL thickness, RNFL thickness, RPE deformation, IS/OS thickness
Glaucoma analysisRNFL, ONH morphology, DDLS, Ganglion analysis as RNFL+GCL+IP and GCL+IPL, OU and Hemisphere asymmetry
AnteriorPachymetry, LASIK flap, Angle Assessment, AIOP, AOD 500/750, TISA 500/750
Anterior Wide ScanAngle to Angle view, Adapter required
Min.  pupil size3 mm
Focus adjustment range-25D to +25D
Dimension/weight382 (W) x 549 (D) × 462 (H) mm
Weight23 kg
Fixation targetOLED display (The target shape and position can be changed), External fixation arm
Power supply110-230 V,  60/50 Hz
Power consumption115 - 140 VA

 

\r\n

 Consists of:

\r\n


(1) 8006 Double Endoscope Channel brush
(1) 8095 Suction Port Brush
(1) 8093 General All Purpose Brush

\r\n

Conveniently packaged 25 per box.

\r\n
    \r\n
  • Realistic Cost
  • \r\n
  • Packaged for single use/prevents cross contamination
  • \r\n
  • Telemed Systems brushes are high quality nylon full bristle scrubbing brushes
  • \r\n
  • Blunt end tip brushes protect delicate channels
  • \r\n
  • Designed for use with endoscopes to achieve excellent all around cleaning
  • \r\n
\r\n




\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n
\r\n

Order/Ref #

\r\n
\r\n

Squeeky Clean Disposable Brush Specifications

\r\n
\r\n

8007

\r\n
\r\n

Endoscope Brush Kit, contains one of each 8006, 8095 and 8093

\r\n
\r\n

 

\r\n
\r\n

 

\r\n
\r\n

8006

\r\n
\r\n

Double Brushed Cleaning Brush, 260cm

\r\n
\r\n

8095

\r\n
\r\n

Suction Port Brush, Double Ended

\r\n
\r\n

8093

\r\n
\r\n

General All Purpose Brush

\r\n